• High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
  • High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
  • High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
  • High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
  • High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
  • High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use

High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use

Classification: Imaging Diagnostic Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Group: Female
Dimension: 360mm*310mm*120mm
Voltage: AC100~240V, 50/60Hz
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
HMF-1200G
Weight
5.3kg
Display
12.1" Color TFT LED
Transport Package
Carton
Specification
CE, ISO
Trademark
Healicom
Origin
China
Production Capacity
1000

Product Description

 

Product Description

HM-1200G Medical Equipment Portable Fetus CTG Fetal Doppler Monitor
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use

The 12.1 inches high-tech fetal monitor offers a reliable, high-performance solution for fetal monitoring needs in doctors' practices, clinics and hospitals, from pre-natal check-ups to antepartum monitoring of high-risk pregnancies.


Features
Core
1. Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
2. Support storage of 25000 groups of medical record and 8640 hours trend review
Body
1. 12.1 inch Folded high-brightness TFT LED
2. Optional touch screen
3. Humanized probe frame design
Sensor
1. 12-Crystal ultrasound transducer achieves a wider focal region for more uniform coverage at greater depths than conventional 9-crystal. 12-crystal ultrasound design can also get good result even when the patient varies her position and shape
2. Optional waterproof FHR transducer for underwater birth
3. Event Marker for easy documentation of events and kick counts. Auto-fetal-movement detector is also available.
4. Use of signal strength indicator to position the ultrasound transducers at the optimum location on the patient
Printer
1. Built-in high-speed thermal printer, printing width can be set to 112mm, 150mm, can meet both US standard and European standard (Brand: SEIKO, Japan)
2. Support fast printing of stored trend
Central System
1. Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
2. Optional Support HL7 (Health Level Seven)
Alarm
1. Three-level acousto-optic alarm
2. FHR signal strength prompt
3. Cross-Channel Verification (CCV) provides visual and audible indication when it detects synchronous fetal or maternal heart rate signals, indicating that you may be monitoring a duplicate signal)
4. Sensor-off alarm
5. Paper out alarm
6. Support alarm review
Linux OS
1. Support operation with mouse and computer keyboard (option)
2. Multi-display mode to meet different clinical requirement, including Fetal-parameter interface, Maternal-parameter interface, Fetal/Maternal-parameter interface, as well as big font, alarm review, ECG review, trend table, trend graph and OxyCRG display.
3. NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
4. On-screen scrolling for viewing stored fetal traces
5. Generate ID automatically when register a new patient
Support medical history search by patient ID, name and mobile number
6. NST Timer
7. Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements
8. Heart rate offset mode allowing you to offset FHR2 ± 5~30BPM.
9. Support multi-language display
10. Advanced Fischer NST Report (Fetal Health Report)
11. Support online software upgrading by net/USB
12. Optional patient data/NST Report backup by USB in PDF format
 
Interface
Transducer socket
1. US1 (FHR1)
2. US2 (FHR 2)
3. TOCO
4. FM (Manual Fetal movement)
5. ECG (Maternal ECG)
6. TEMP (Maternal temperature)
7. SPO2 (Maternal SpO2)
8. NIBP (Maternal NIBP)
LAN / Central monitor system interface
The LAN port is for connecting the monitor to a central monitor system network.
Input device interface
1. This optional interface provides two USB ports to enable the monitor to be connected to off-the-shelf input devices as well as support patient data & NST Report backup (option).
2. Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
3. Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
4. Knob (Standard)
5. Touch screen (optional)
[Remark: Touch screen can not be used simultaneously with
mouse / computer keyboard.]
 
Service Features
1. The Support Tool helps technical personnel to
- carry out configuration, upgrades and troubleshooting on an individual monitor.
- back up the monitor settings.
2. The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Printer Setting, Skin Type, AFM Setting, Brightness Setting, Clear Data, NIBP Calibration, and Touch Screen Calibration.
3. The Support Tool uses the USB interface of the fetal monitor for software upgrading
 
Performance Specifications
Dimension and Weight
- Dimension: 360mm*310mm*120mm
- Weight: 5.3kg(excluding accessories)
Power Supply
- Voltage: AC100~240V, 50/60HZ
Display
- 12.1" color TFT LED (0-90° rotation)
- Resolution: 1024*768 pixels
Battery (Built-in)
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours
Recorder (Built-in)
- Method: Thermal printer
- Paper: Z-fold, thermosensitive
- Paper width: 112 mm (4.41 in)/150 mm (5.91 in)
- Printing speed: 1/2/3cm/min
- Trace: Max. 4 tracks
- Recording way: Real-time Recording, Review Printing
Alarm
- Level: Low, medium and high
- Indication: Auditory, Visual, Delay of FHR Alarm
Input Device
- Touch screen (option)
- Knob (Standard)
- Keypad input (Standard)
- Mouse/ Keyboard input (option)
- USB port for patient data/NST report backup
(option)
System Output & Extensible
Interface
- Ethernet Network: 1 standard RJ45 socket
- USB Port: 2
- Video Output: 1 HDMI port (option)
Trend & Reviewing
- Cardiotocography (CTG):
Waveform Review: 8640 hours
- Vital Signs:
Trend: 2160 hours
Waveform Review: 2 hours
NIBP Review: 2000 groups
- Alarm Review: 2000 groups
Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting
Ultrasound (FHR)
- Transducer type: 12-Crystal ultrasound transducer
- Measure method: Wide beam pulse doppler
- FHR Measurement range:
30 to 240 bpm (US Standard)
50 to 210 bpm (Europe Standard)
- Accuracy: ±1 bpm
- Intensity: <3 mW/cm2
- Ultrasound frequency: 1MHz±3%
- Resolution: 1 bpm
TOCO
- Measurement method: Strain gauge sensor element
- Measure range: 0 ~ 100 units
- Resolution: 1 unit
- Nonlinear deviation : ≤±8%
- Baseline setting: 0,5,10,15, 20 can be selected
- Auto offset correction: 3 second after connecting the transducer
- Auto zero adjust: TOCO value is set to zero negative following a negative Measure value for 5 seconds
Fetal Movement Recording
- Automatic fetal movement (AFM): pulsed doppler ultrasound
- Automatic fetal movement autograph
- Manual fetal movement marker (MFM)
Maternal ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto
- Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- CMRR: Diagnostic Mode >89 dB
Monitor Mode >105 dB
Surgery Mode >105 dB
- Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
Maternal Heart Rate
- Measure range: Adult: 0bpm; 10 ~ 300 bpm
Neonate: 0bpm; 10 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV ~ +0.8mV: ±0.02mV or ±10%, whichever is greater
- Other range: unspecified
- Resolution: 0.01mV
Maternal Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2, ×4
- Respiration Rate: 0bpm, 6 ~ 150 bpm
- Resolution: 1 bpm
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Apnea Alarm: 10 ~ 60 s
Maternal SpO2 (Digital Technic)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Pulse Rate
- Range: 25~250bpm
- Accuracy: ±1% or ±1 bpm, whichever is greater
- Resolution: 1bpm
Maternal NIBP (MNIBP)
- Method: Oscillometric
- Measure mode Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Systolic: 30~270 mmHg
Diastolic: 10~220 mmHg
Mean: 20~235 mmHg
- Static pressure accuracy ±3mmHg
- Resolution: 1mmHg
- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
- Over pressure Protection: Dual protection via software & hardware
Maternal Temperature
- Technique: Thermistor probe (2.25K)
- Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
- Unit: Celsius (ºC), Fahrenheit ( ºF)
- Resolution: 0.1ºC
- Accuracy: ±0.1ºC
NST Report/FHR Interpretation
(Option)
- Based on Fischer Evaluation Method (monitoring time ≥20 Min)
- Average Baseline FHR / Number of Acceleration / Number of Deceleration / Number of Small Acceleration / Amplitude Variation / Number of PV
- Automatic Score Result: Sore: 8-10 (Excellent)
Sore: 5-7 (Suspicious)
Score:≤4 ( Fetus Hypoxia)
 
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
 
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use
High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use

 

Company Profile

High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital UseHigh Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital UseHigh Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital UseHigh Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use

 

FAQ

1. What about the price level? 
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts. 

2. Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper.

3. What is time of delivery? 
Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible. 

4. What about quality assurance? 
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. 

5. What is payment terms? 
T/T, Credit Card, L/C, Western Union, PayPal, MoneyGram. 

High Quality Portable Baby Mother Fetal Pregnancies Monitor for Hospital Use


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now