Basic Info
  • Model NO.: H-800
  • Medical Device Regulatory Type: Type 3
  • Air Temperature: 20°c~37°c
  • Infant Bed Max Load: 10kg
  • Warranty: 12 Months
  • Specification: CE, ISO
  • HS Code: 9018909090
  • Medical Devices Reg./Record No.: Gsyjxzz20123540587
  • Power Input: ≤400va
  • Temperature Rise Time: ≤30min
  • Certificate: CE, ISO
  • Trademark: Healicom
  • Origin: Jiangsu, China
Product Description
Standard Composition
 1 Servo Control Mode: air temp;
 2 Instant Parameter Displaying: set temp, air temp, heat power rate;
 3 Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
 4 Power failure reset memory and self-test function;
 5 Hood with dual slope: 4 hand-ports
 
Specification
PowerModel H-800-1E110 / 120 V ac, 50Hz / 60Hz
Model H-800-2E220 / 240 V ac, 50Hz / 60Hz
Power Input≤400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF 
Its operation is continuous
AlarmPower AlarmPower Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm Fan Failure: Activates if Fan motor malfunctions
Sensor AlarmAir Sensor Failure: Air Sensor malfunction, refer unit to service
Deviation AlarmHigh Air Temperature: Activated if displayed Air Temperature is 15°C above set point
Low Air Temperature: Activated if displayed Air Temperature is 25°C below set point
Over Temperature AlarmOver Air Temperature: Activated when displayed Air Temperature was approach 38°C in Air Mode
System AlarmSystem Failure: Activated if Temperature Control System malfunctions
Temperature Control Range and Correlative SpecificationsAir Temperature20°C~37°C
Temperature Rise Time≤30min
Temperature Variability±0.5°C
Temperature Uniformity≤1°C
Environment RequirementEnvironment TemperatureOperation Temperature Range+20°C~+30°C
Store Temperature Range-40°C~+55°C
Environment HumidityOperation Humidity Range30%~75%
Store Humidity Range10%~100%
Atmospheric Pressure Range700hPa~1060hPa
Other
Specifications
Noise Level Within Hood Environment≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the HoodLess than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattressless than 0.3m/s
Infant Bed Max Load10kg
Transfusion Shelf Max Load2kg
Factory Default SettingsTemperature Control Mode Air Temperature Mode
Air Set Temperature: 32°C
Temperature Units:°C
 
NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperatureH-800 Medical Equipment Qualified & Cheap Infant Incubator
 