CE Approved Medical Table Top Oximeter with NIBP

FOB Price: US $285 / Piece
Min. Order: 2 Pieces
Min. Order FOB Price
2 Pieces US $285/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 1000units Per Month
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HP-810
  • Type: Patient/Fetal/Maternal Monitor
  • Group: All
  • Waveforms: SpO2 Waveform
  • Pr Accuracy: ±1bpm or ±1%(The Larger One)
  • Pr Power Consumption: Below 30mA
  • Storage Temperature: -10°c-40°c
  • SpO2 Resolution: ±1%
  • Transport Package: Carton
  • Origin: Jiangsu, China
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, ISO13485
  • Parameters: Three Parameters: SpO2, Pulse Rate, NIBP
  • Pr Measurement: 30bpm-240bpm
  • Pr Power: Two AAA 1.5V Alkaline Batteries
  • Operation Temperature: 5°c-40°c,
  • Air Pressure: 70kpa-106kpa
  • Trademark: Healicom
  • Specification: CE, ISO
  • HS Code: 9018909090
Product Description
Parameters
Three Parameters: SPO2, Pulse Rate, NIBP
 
Waveforms
SpO2 Waveform
 
Features
COLOR OLED display, four direction adjustable.
SpO2 and pulse monitoring, and Waveform display.
Low-power consumption, continuously work for 50 hours.
Small in size, light in weight, and convenient to carry.
Low voltage alarm display, Auto power-off.
Runs on standard AAA batteries.
 
Detailed descriptions of product functions:
SPO2
Measurement range: 70%-99%
Accuracy: ±2% on the stage of 70%-99%, unspecified(<70%) for SPO2
Resolution: ±1%
Low perfusion: <0.4%
PR
Measurement: range:30BPM-240BPM
Accuracy: ±1BPM or ±1%(the larger one)
Power: two AAA 1.5V alkaline batteries
Power consumption: below 30mA
Automatic power-off: the product shuts down automatically after no signal for 8 seconds
Dimension: 62mm×32mm×33mm
Operation environment:
  Operation temperature: 5°C-40°C,
  Storage temperature: -10°C-40°C
  Ambient humidity: 15%-80% on operation,
                  10%-80% in storage
  Air pressure: 70kPa-106kPa
NIBP monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto/continuous.
Auto measurement interval: adjustable from 1 to 255 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and hardware.
Range: Adult:
 Systolic pressure: 40mmHg~270mmHg
 Mean pressure: 20mmHg~235mmHg
 Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
 Systolic pressure: 40mmHg~200mmHg
 Mean pressure: 20mmHg~165mmHg
 Diastolic Pressure: 10mmHg~150mmHg
Neonate
Systolic pressure40mmHg~135mmHg
Mean pressure20mmHg~110mmHg
Diastolic Pressure10mmHg~100mmHg
Upper and lower limit of alarm

CE Approved Medical Table Top Oximeter with NIBPCE Approved Medical Table Top Oximeter with NIBPCE Approved Medical Table Top Oximeter with NIBPCE Approved Medical Table Top Oximeter with NIBPCE Approved Medical Table Top Oximeter with NIBPCE Approved Medical Table Top Oximeter with NIBP