Basic Info
  • Model NO.: HV-400A
  • Kind: Surgical Equipment
  • Group: All People
  • Medical Device Regulatory Type: Type 3
  • Certificate: CE ISO
  • Gas Requirement: Medical Oxygen and Nitrous Oxide
  • Modes of Ventilation: A/C, Ippv, Sippv, Imv, Simv, Peet. Manual,Sigh etc
  • Peep: 0.1 ~ 1.0 Kpa
  • Imv Frequency: 1~20 Bpm
  • Trademark: healicom
  • Origin: Jiangsu, China
  • Type: Ventilator
  • Certification: CE, ISO13485
  • LCD Display: With LCD Display
  • Medical Devices Reg./Record No.: Gsyjxz20143540786
  • Display: 10.4′′ LCD Display
  • Safety Valve: <12.5 Kpa
  • Ventilator Compliance: ≤30 Ml/Kpa
  • Ptr: -10 ~ 10 Hpa
  • I/E Ratio: 4:1~1:4, Has The Inverse Ratio Ventilation
  • Specification: CE ISO
  • HS Code: 9019200000
Product Description
Prospective service and support
The HV-400A ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
 
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour.
 
Component Details
Display: 10.4''LCD Display Following Parameters & Real time waveform display
Operating mode and respiratory rate;
--Ventilator control frequency set by medical staff;
--Tidal volume of each breath in the patient;
--Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
--Expiratory phase and inspiratory phase and actual respiratory rate;
--Minute volume;
--Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;
--Real-time variation in internal airway pressure.
 
Ventilator Construction:
--Environmental Protection Material construction, hardly to be broken.
--Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
 

TECHNIQUES SPECIFICATIONS

Physical specifications

Display

10.4'' LCD Display

Mode

pneumatically powered and electrically controlled system

Trolley

Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

Technical Specifications:

Gas requirement

Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa

safety valve

<12.5  kPa

Respiratory Rate

1 ~ 99 bpm

Maximum Minute ventilation

≥18L / min

modes of ventilation

A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT

Ventilator compliance

≤30 Ml/kPa

PEEP

0 ~ 1.0 kPa

Ptr

-10 ~ 10 hPa

IMV frequency

1~20 bpm

I/E Ratio

4:1~1:4, Has the inverse ratio ventilation

Tidal Volume

Setting Range:  50~1500ML   Display Range: 0~2000ml ;  resolution ratio: 10ml

Inspiratory Plateau

0~1s

Maximum Safety  Pressure

≤ 6.0kPa

Sigh

one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point

Pressure limit range

1.0~ 6.0kPa

Airway pressure alarm: Audible and visual and with yellow and red color indicating

Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0  kPa

±0.2 kPa

Ventilation Volume alarm

≥ 18L/ MIN

Power Supply Alarm

Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s

Operating conditions

Ambient temperature

10 ~ 40oC

Relative humidity:

no higher than 80 %

Atmospheric pressure

860 hPa ~ 1060 hPa

Power requirement

100-120 Vac, 50/60 Hz; 

Attention: the AC power supply used for the ventilator machine must be well grounded.

Storage

Ambient temperature

-15oC ~ +50oC

Relative humidity

no higher than 95 %

Atmospheric pressure

86 kPa ~ 106 kPa.

It should be stored in a room without corrosive gas and well ventilated

Package

packaging box

comply with the requirement of GB/T 15464

Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation

Moisture protection and rain protection to ensure that product is protected from natural damage.

Safty & Alarm

Gas source pressure

Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.

Airway Pressure Alarm

The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.

Tidal Volume Alarm

Lower than 50ml, The alarm will be raised after one breathing cycle.

Ventilation Volume Alarm

Lower: 0~12L/Min;  
Up: 18L/ Min

Battery Voltage Alarm

It alrms when the battery voltage is lower than 10.5V.

Power On Self Test

Self test before working, assure it's working normally.
 

STANDARD CONFIGURATIONS

QTY

NAME

1 set

Main unit

1 set

Oxygen tube

2 set

Silicone Mask

1 pc

Power line

4 pcs

Threaded pipe

2 pcs

Standard Pipe

1 set

Oxygen Reducer

1 set

Humidifier

1 pc

Battery

2 set

flow sensor

2 pcs

A leather bag ( Blue)

1 set

Tools with the machine

1 set

User Manual (English Version)
Hot Sale HV-400A Hospital Ventilator PriceHot Sale HV-400A Hospital Ventilator PriceHot Sale HV-400A Hospital Ventilator PriceHot Sale HV-400A Hospital Ventilator PriceHot Sale HV-400A Hospital Ventilator PriceHot Sale HV-400A Hospital Ventilator Price
Send your message to this supplier
Avatar
Miss Kelly
*From:
To: Miss Kelly
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now