Hospital Clinical Infant Incubator with CE (H-800)

FOB Price: US $900-901 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $900-901/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 50000PCS/Year
Payment Terms: T/T, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: H-800
  • Certification: CE
  • Group: Infant
  • Medical Devices Reg./Record No.: Gsyjxz20123540587
  • Temperature Rise Time: ≤30min
  • Temperature Uniformity: ≤1°c
  • Trademark: Healicom
  • Specification: ISO
  • HS Code: 90189090
  • Type: Infant Incubator
  • LCD Display: Without LCD Display
  • Medical Device Regulatory Type: Type 2
  • Temperature Control Mode: Air Control
  • Temperature Variability: ±0.5°c
  • Air Temperature: 20°c~37°c
  • Transport Package: Carton
  • Origin: China
Product Description
Standard Composition:
1. Servo Control Mode: air temp;
2. Instant Parameter Displaying: set temp, air temp, heat power rate;
3. Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
4. Power failure reset memory and self-test function;
5. Hood with dual slope: 4 hand-ports
 
Specification:
PowerModel H-800-1E110 / 120 V ac, 50Hz / 60Hz
Model H-800-2E220 / 240 V ac, 50Hz / 60Hz
Power Input≤400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF 
Its operation is continuous
AlarmPower AlarmPower Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm Fan Failure: Activates if Fan motor malfunctions
Sensor AlarmAir Sensor Failure: Air Sensor malfunction, refer unit to service
Deviation AlarmHigh Air Temperature: Activated if displayed Air Temperature is 15°C above set point
Low Air Temperature: Activated if displayed Air Temperature is 25°C below set point
Over Temperature AlarmOver Air Temperature: Activated when displayed Air Temperature was approach 38°C in Air Mode
System AlarmSystem Failure: Activated if Temperature Control System malfunctions
Temperature Control Range and Correlative SpecificationsAir Temperature20°C~37°C
Temperature Rise Time≤30min
Temperature Variability±0.5°C
Temperature Uniformity≤1°C
Environment RequirementEnvironment TemperatureOperation Temperature Range+20°C~+30°C
Store Temperature Range-40°C~+55°C
Environment HumidityOperation Humidity Range30%~75%
Store Humidity Range10%~100%
Atmospheric Pressure Range700hPa~1060hPa
Other
Specifications
Noise Level Within Hood Environment≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the HoodLess than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattressless than 0.3m/s
Infant Bed Max Load10kg
Transfusion Shelf Max Load2kg
Factory Default SettingsTemperature Control Mode Air Temperature Mode
Air Set Temperature: 32°C
Temperature Units:°C
 