Basic Info
  • Model NO.: H-2000
  • Certification: CE, ISO13485
  • Control Mode: Air Temp,Skin Temp
  • Instant Parameter Displaying: Set Temp, Air Temp ,Skin Temp,Heater Power Rate
  • Tubing Grommets: 4
  • Skintemp Control Range: 30°c~37°c
  • Noise Level Within Hood Environment: ≤55db
  • Trademark: Healicom
  • Specification: High quality
  • HS Code: 90189090
  • Theory: Infant Incubator
  • Group: Infant
  • Audible & Visual Alarms: Power Failure, Sensor Failure, Higher & Lower Temp
  • Operate Port: 6 (2 Iris Ports)
  • Airtemp Control Range: 20°c~37°c
  • Skin Temp Sensor Accuracy: ≤0.3°c
  • Infant Bed Tilt Adjusting: ±10° Step-Less
  • Transport Package: Wooden Carton
  • Origin: China
Product Description
Infant Incubator (H-2000)
STANDARD COMPOSITION:
Servo Control Mode:Air temp, skin temp;
Instant Parameter Displaying:Set temp, air temp ,skin temp, heater power rate;
Audible & Visual Alarms:Power failure, sensor failure, higher & lower temp, air& skin temp override, fan failure, system failure;
>37°C Preset Mode:Power failure reset memory, alarm silence, keypad lock, self-test function;
Hood with dual slope:6 hand-ports;Left & right cabinets, top-shelf;
RS-232 Output Connector (Use for network system )

SPECIFICATION
POWER
Model H-2000-1E:110 / 120 V ac, 50Hz / 60Hz
Model H-2000-2E:220 / 240 V ac, 50Hz / 60Hz
Power Input:≤400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF Its operation is continuous
ALARM
Power Alarm
Power Failure:Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm
Fan Failure:Activates if Fan motor malfunctions
Sensor Alarm
Air Sensor Failure:Air Sensor malfunction, refer unit to service
Sensor Out of Position:Activated when Sensor is not in correct position to perform calibration or continue operation
Skin Sensor Disconnected:Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller
Skin Sensor Failure:Activated when Skin Sensor malfunctions
Deviation Alarm
High Air Temperature:Activated if displayed Air Temperature is 15°C above set point
Low Air Temperature:Activated if displayed Air Temperature is 25°C below set point
High Skin Temperature:Activated if displayed Skin Temperature is 10°C above set point
Low Skin Temperature:Activated if displayed Skin Temperature is 10°C below set point
Over Temperature Alarm
Over Air Temperature:Activated when displayed Air Temperature was approach 38°C for set temperature ≤37°C, or approach 40°C for set temperature >37°C in Air Mode
Over Skin Temperature:Activated when displayed Skin Temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C in Skin Mode
System Alarm
System Failure:Activated if Temperature Control System malfunctions

TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS
Air Temperature:20°C~37°C,for set temperature ≤37°C, 37°C~39°C, for set temperature >37°C
Skin Temperature:20°C~37°C,for set temperature ≤37°C, 37°C~38°C, for set temperature >37°C
Temperature Rise Time :≤30min
Temperature Variability:±05°C
Temperature Uniformity:≤1°C
Skin Sensor Precision:≤03°C
ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range:+20°C ~ +30°C
Store Temperature Range:-40°C ~ +55°C
Environment Humidity
Operation Humidity Range:30%~75%
Store Humidity Range:10%~100%
Atmospheric Pressure Range:700hPa~1060hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment:≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood:Less than 05% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattress:Less than 035m/s
Infant Bed Max Load:10kg
Transfusion Shelf Max Load:2kg
Cabinet Max Load:6kg
FUNCTION OF ""SILENCE KEY
Make the alarm to be silence for 10 minutes by press this key, following:
Deviation Alarm
Sensor Alarm
Fan Alarm
FACTORY DEFAULT SETTINGS
Temperature Control Mode Air Temperature Mode
Air Set Temperature:32°C
Skin Set Temperature:34°C
Temperature Units:°C

NOTE:Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature
 
Specification
Specifications of hoodH-3000H-2000H-1000H-800
Mattress to Hood450 mm450 mm450 mm410 mm
Observation side of hoodTwo inclineTwo inclineTwo inclineTwo incline
Operate port6 (2 Iris ports)6 (2 Iris ports)6 (2 Iris ports)4 (2 Iris ports)
Tubing grommets4442
Front access panel826×310 mm826×310 mm826×310 mm826×280 mm
Mattress Tray Size630×360 mm630×360 mm630×360 mm630×360 mm
Technical Specification
Power requirement≤400VA≤400VA≤400VA≤400VA
Temperature control modeAir and skin servo controlAir and skin servo controlAir servo controlAir servo control
AirTemp Control Range20°C~37°C20°C~37°C20°C~37°C20°C~37°C
Temperature override mode to20°C~39°C20°C~39°C20°C~39°C----
SkinTemp Control Range30°C~37°C30°C~37°C--------
Temperature override mode to30°C~38°C30°C~38°C--------
Skin temp sensor accuracy≤0.3°C≤0.3°C--------
Humidity display range5%~99%------------
Temperature fluctuation≤0.5°C≤0.5°C≤0.5°C≤0.5°C
Mattress temperature uniformity≤0.8°C≤0.8°C≤0.8°C≤0.8°C
Temperature rise time≤30 min≤30 min≤30 min≤30 min
Noise level within hood environment≤55dB≤55dB≤55dB≤55dB
Alarm
Power failure alarmYesYesYesYes
Fan failure alarmYesYesYesYes
Sensor failure alarmYesYesYesYes
High air temperature alarm+15°C+15°C+15°C+15°C
Low air temperature alarm-25°C-25°C-25°C-25°C
High skin temperature alarm+10°C+10°C--------
Low skin temperature alarm-10°C-10°C--------
Over air temperature alarm≤38.0°C; ≤40.0°C≤38.0°C; ≤40.0°C≤38.0°C; ≤40.0°C≤38.0°C
Over skin temperature alarm≤38.0°C; ≤39.0°C≤38.0°C; ≤39.0°C≤38.0°C; ≤39.0°C----
System failure alarmYesYesYes----
Alarm silence functionYesYesYes----
Operational condition
Environment temperature+20°C~+30°C+20°C~+30°C+20°C~+30°C+20°C~+30°C
Environment relative humidity5%~99%5%~99%5%~99%5%~99%
Environment air velocity of flow<0.3m/s<0.3m/s<0.3m/s<0.3m/s
Others
RS-232ConnectorYesYesYes-----
RailYesYesYes-----
Infant bed tilt adjusting±10° step-less±10° step-less±10° step-less-----
Mattress tray Max load10kg10kg10kg10kg
Transfusion pole Max load2kg2kg2kg2kg
Cabinet Max load6kg6kg6kg----
Packing size (2 cartons)100×58×80 cm100×58×80 cm100×58×80 cm100×58×98 cm(1 carton)
Gross weight120kgs120kgs120kgs83kgs
Send your message to this supplier
Avatar
Miss Maggie
*From:
To: Miss Maggie
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now