Sterilizer, Autoclave, Autoclave Sterilizer manufacturer / supplier in China, offering 150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A), Hospital Clinic Use Electrical Surgical Operation Room Operating Theatre Table, Radiography Detector Wired or Wireless Portable Digital X-ray Flat Panel and so on.

Diamond Member Since 2011
Audited Supplier
Supplier Homepage Products 01.Autoclave&Drying oven Horizontal Cylindrical Autoclave Sterilizer 150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)

150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $3,000-3,800/ Piece
Port: Tianjin, China
Production Capacity: 50000PCS/Year
Payment Terms: T/T, Western Union
Theory: Pressure Steam
Type: Pressure Steam Sterilization Equipments
Certification: CE, ISO13485
Electric Tension: 220V/380V
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Sterilization Information Recording and Printing: Without Sterilization Information Recording and Printing

You Might Also Like

Loading...

Basic Info

Model NO.
HS-150A
Material
Stainless Steel
Sterilizing Chamber Volume
150 / 200 / 280L
Working Pressure
0.22MPa
Time of Sterilization
0-60 Min
Time of Drying
0-60 Min
Heat Average
≤±1°c
Trademark
Healicom
Transport Package
Wooden Carton
Specification
High quality
Origin
China
HS Code
8419200000
 Horizontal Cylindrical Pressure Steam Sterilizer
150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)

Characteristics:

 1. The steam can't go through to chamber when the door don't close, and the pilot off inform. You can process dry operation.

 2. When the pressure inner over 0,027MPa.the door be locked and can't be open.

 3. If you not choose the sterilize time and start the machine, buzzer sound will be alarm.

 4. Opening the door by mistake in the course of start, the jacker valve and chamber valve will auto shut-off.

 5. Lacking water the pilot light on, heating and sterilize pilot light off, the buzzer sound and auto release steam.

 6. Overload and leakage protection, when leakage or over current occur, it auto off the power.

 7. Temperature controlled not work and the inner pressure over 0.165MPa, the safety valve auto start open.

Specification:

 

HS-150A

HS-200A

HS-280A

Sterilizing chamber volume

150L φ440×1000m

200L φ515×1000mm

280L φ600×1000mm

working pressure

0.22MPa

working  temperature

134ºC

Adjustment of temperature

105ºC - 134ºC

Time of sterilization

0-60 min

Time of drying

0-60 min

Heat average

≤±1ºC

Power

9KW/380V 50Hz

9KW/380V 50Hz

12KW/380V 50Hz

Dimension

1400×600×1300

1400×670×1650

1400×770×1780

Transport dimension

1550×750×1850

1560×820×1850

1680×920×2100

G.W/N.W

320/240 KG

350/260 KG

465/365 KG

150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)

150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)
150L / 200L / 280L Horizontal Cylindrical Pressure Autoclave Steam Sterilizer (HS-150A)
 

Send your message to this supplier

*From:
*To:
avatar Miss Tina
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Loading...

Product Groups

Contact Supplier

Miss Tina
Sales Manager