| Customization: | Available |
|---|---|
| Power: | AC220V±10% |
| Display: | Colour LCD |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hospital Equipment Medical Surgical Hv-3010 ICU Ventilator

Features:
1.12.1 inch touch screen with desirable color schemes
2.The simplest interface boots a precise control and
convenient operation
3.Applied for adult,pediatric and infant
4.Multi-mode ventilation function (VCV, SIMV,
SIMV/PSV,PSV, PCV, APNEA,CPAP, BIPAP,Manual, SIGH)
5.Applied with Invasive ventilation and Non-invasive ventilation
6.Advanced air compressor for air input
7.Self testing and calibration function
8.Design of intelligent flashing alarm indicator(Priority alarm,
secondary alarm)
9.Auto-wash for exhaust valve
Assistant Nebulization treatment , High flow oxygen Therapy
Technical Data:
| Physical Specifications | |
| Dimensions | 45*55*140cm |
| Weight | 65kg |
| Casters | Front wheels with lock |
| Screen | 12.1 inch touch screen |
| Display | Colour LCD |
| Display graphics | Waveforms of P-T, F-T, V_T |
| Loops . | P_V, F-V, F-P |
| Pipeline Supply | |
| Gas configuration | O2, Air |
| Pipeline input range | 280-600kPa |
| Air Compressor Specifications | |
| Power | AC 220V±10%,50Hz ±2% |
| Output pressure | 0.4+0.1MPa |
| Noise | ≤50dB |
| Battery Power | |
| Battery Type | Lead-acid 12V, 4Ah |
| Run-time | Typical 180 mins+ |
| Ventilator Seclfiations | |
| VCA | Volume control ventilation |
| APNEA | APNEA |
| SIMV | Synchronized Itrmittent Mandatory Ventilation |
| SIMV/PSV | SIMV/Pressure support |
| MANUAL | Manual |
| CPAP | Continuous Positive Airway Pressure |
| PSV | Pressure Support Ventilation |
| PCV | Pressure Control Ventilation |
| NIV | Non-invasive venilation |
| BIPAP | BIPAP |
| SIGH | SIGH |
| ARPV | optional |
| Ventilator Parameter | |
| TIdal Volume range | 20-2000ml (10ml optional) |
| Pressure range | 5-80 cmH2O |
| Rispriation Rate Range | 1-100bpm (1-40bpm under SIMV) |
| 1:E Range | 4:1-1:8 . |
| Oxygen concentration | 21%-100% |
| Ptigger Range | -20-0cmH2O |
| Apnea TI Range | 0-6s |
| PEEP | |
| Type | Integrated, Electronic control |
| Range | 0-40cmH2O |
| Alarm Limits | |
| VIsual | No tidal volume, MV,Paw, FiO2 litationO2, |
| Alir failure, AC power failure, backup low | |
| Audio | No tidal volume, MV,Paw, FiO2 litation |
| Pre-setting Functions | |
| Language | Englih |
| Calibration | AUTOMATIC |
| Optional | |
| Aixlliary Suction function | |
| O2 remedy | |
| Communication port | RS-232,VGA,Ethemet, USB (Optional) |
| Environmental Conditions | |
| Operating Temp | 5°C-40°C |
| Storage Temp | -10°C-+40°C . |
| Humidity | ≤80 % |
| Atmosphere pressure | 960 hPa~1040 hPa |