Gold Member Since 2011
Audited Supplier
Healicom Medical Equipment Co., Limited

X Ray, Digital X Ray, Digital X Ray Machine Price manufacturer / supplier in China, offering Medical HDF-6000 High Frequency Digital X Ray Machine, H-100 LED Neonatal Phototherapy Unit Incubator, H-100 Medical Equipment Infant Phototherapy Unit Incubator and so on.

(/ )

Supplier Homepage Product X-ray machine DR Medical HDF-6000 High Frequency Digital X Ray Machine

Medical HDF-6000 High Frequency Digital X Ray Machine

FOB Price: US $66,200 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $66,200/ Piece
Get Latest Price
Production Capacity: 1000 Units Per Month
Transport Package: Wooden Case
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HDF-6000
  • Type: X Ray Equipment
  • Group: All People
  • Medical Devices Reg./Record No.: Gsyjxz20123301226
  • Power Output: 50kw
  • Rotation of The Table: 90°~0°~-25°, Speed >4°/Sec
  • Inverter Frequency: 100 kHz
  • Thermal Capacity: 210kj
  • Capacity: ≥65kVA
  • Specification: CE ISO
  • HS Code: 9022140090
  • Classification: Imaging Diagnostic Equipment
  • Certification: CE, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Certificate: CE ISO
  • Power Supply: 380V±38V
  • Frequency: 50Hz±1Hz
  • Control Interface: Intelligent Touch LCD
  • Transverse Travel of Table: ±110mm
  • Trademark: healicom
  • Origin: Jiangsu, China
Product Description
I Use
The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other Traumatic Radiography etc of X-ray routine examination:
1. Fluoroscopy: Can be used for gastrointestinal fluoroscopy, gastrointestinal imaging, cholangiography, Urinary tract imaging and Deep vein imaging and other imagines; Can used for fluoroscopy of esophagus, breast, gastrointestinal, Abdomen and limbs and spot film photography; Can do the operation of Fracture reduction and Taking foreign body from in vivo. Gastrography, Esophagography, Myelography, Arthrography, cholangiography, bronchography, venography, angiography, urography, and hysterosalpingography, etc.
2. Radiography: chest radiography, head and whole body bone radiography, Pediatric Radiology, and treat application several intervention radiology.

II Main Specifications
ItemContentTechnical parameter
Power supplyVoltage380V±38V
Frequency50Hz±1Hz
Capacity≥65kVA
internal resistor≤0.17Ω
Digital X-ray high voltage system (import high-frequency generator )
 
 Power Output50KW
 Inverter Frequency100 kHz
photographyTube Voltage40kv-150kv step regulation
Tube Current10mA-630mA step regulation
Exposure time1.0s-6300ms step regulation
Control interfaceIntelligent touch LCD
fluoroscopyTube Voltage40kv-125kv step: 2kv continuous regulation
Tube Current0.5mA-6mA continuous regulation
Max 10mA (pulse)
Automatic brightness for fluoroscopy IBSAutomatic brightness tracking,multiple settings beforehand 
Digital Controlled X-ray Tube
(Toshiba, Japanese)
ModelE7252
Dual Tube FocusMax:1.2mm / min :0.6mm
Input PowerLarge focus:75kW  small focus: 27kW
thermal capacity210KJ
Rotary anode speed2700rpm
Micro-computer control digital tube remote diagnostic table
 
Material of the tabletopHigh strength, low absorb carbon fiber
Rotation of the table90°~0°~-25°, speed >4°/sec
Table2100*700*12mm, with integrated collimator, patient weight >200 Kg
Transverse travel of table±110mm
Longitudinal travel of the photography holder and film spot device≥720mm
X-ray Focus-film gauge1100 mm- 1500 mm
Rotating foot plate±360° rotation
Full film photography size8″*10″-14″*17″
Dividing method for spot filmFull film, half dividing, three parts dividing, four parts dividing
Control method for diagnostic tableRemote, table control, frequency conversion soft starting and stopping
Beam limiter        Electric Multi-leaf
Voice interactionTwo-way microphone system
Fixed Bucky device for tableGrid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15″×18″
Digital Image TV SystemImage IntensifierTOSHIBA (9″) Image Intensifier
High resolution CCD
(Digital cameras)
Ultra-low-light, 1 mega-pixel, scanning sensor: 2/3", Auto IRIS & ND Filter. Integrated optical system  14 bits
Monitor2 pcs,monitors,14"medical high definition monitor, horizontal central resolution ratio:1000 lines, fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame
(Optional : 19"medical high definition LCD monitor)
Digital Picture Processing System
(CCU Sentinel)
High definition line by line output mode, 8 level noise reduction,store 8 image;LIH(freeze the last frame),the image can be turned vertically and horizontally,positive and negative image; OSD(monitor show)

III. Main features
1. Base the optimization principle to produce, excellent comfit of whole system, satisfy clinical personalized requirement.
2. Latest technology of high frequency mainframe, digital image collection, gain the high quality image easily.
3. Show human-machine interface directly, excellent operation system, make man-machine conversation more conveniently and easy to understand.
4. Multiple safety control, make the image quality and radiation dose to achieve organic balance.
5. Strong function of digital image processing, overall compatible with DICOM network application.
6. Diagnostic table
a. Visual display of man-machine interface, touch screen control, makes man-machine conversation more intuitive, convenient and easy to understand.
b. Programmable controller technology, high control precision, good stability, excellent anti-jamming performance .
c. Inverter control technology, When the table move, it can soft start, soft stop, smooth no noise, more accurate positioning .
d. Reliable, high precision of angular displacement sensor technology, low dynamic noise, and long mechanical life.
e. High-resolution of rotary encoders, high accuracy of auto-slice, security and stability.
f. Rotation range of 90 ° ~ 0 ° ~ -25 °, can take routine examination of digestive organs, can also be used for a variety of special examination .
g. Humanized Design of diagnostic table lateral switch, near station positioning make the operation more convenient.
h. Toshiba's high-quality image intensifier, to further enhance image sharpness, contrast, more easily, to clearly identify Lesions.
i. Move a wide range of spot film device, apply the operation for People do not move with the operation of motor way easily to complete taking from the throat, esophagus, to the lower abdomen of a series of examinations.
j. Spot film box open by self, safe and reliable operation.
7. Generator
a. With X-ray Radiography and perspective function of generator, maximum output power of 50 kW.
b. Output voltage of 150 kV.
c. With a smaller, lighter, modular design.
e. In the exposure process, kV and mA can be adjusted to achieve a constant radiation output.
f. Large screen LCD flat panel used to display the APR conventional conditions and practical projects.
g. User-friendly system configuration.
h. Operator can modify the APR technology items.
i. Provide APR /-ray tube data downloads.
j. A variety of automated diagnostic procedures, and operators with prompts .
k. With serial RS232 communication interface.
l. Operation can be individually programmed for the APR, and APR and manual techniques for programming options.
M. Programmable settings, calibration, and conduct regular APR (by connecting an external computer).
N. ABS (Automatic Brightness Stabilization) circuit select four kinds of kV and mA curve.

IV. Main Product Configuration
Remote Control console1setRadiography Table1set
Multi-leaf beam limiting device1setCCD camera1set
X-ray tube assembly1setHigh voltage cable1set
X-ray generator1sethigh definition medical monitor2sets
Image intensifier1setDigital image system1set
Send your message to this supplier
Avatar
Miss Kelly
*From:
To: Miss Kelly
*Message:

Enter between 20 to 4,000 characters.