• Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
  • Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
  • Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
  • Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
  • Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit

Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit

Type: Vet Pulse Oximeter
Product Name: Vet Pulse Oximeter
Display Mode: Color Display
SpO2 Measurement Range: 0%~100 % (Resolution: 1%)
Accuracy: 70%-100%: ± 2% 0%-69%: Unspecified
Pr Measurement Range: 30 Bpm-250 Bpm (Resolulion: 1 Bpm)
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
WT60D
Power Consumption
<100 Ma
Voltage
DC 3.0 V
Power Supply
Two AA Batteries
Continuous Working Time
44 Hours in Theory
Safety Class
Internally Powered Equipment, Type Bf Applied Part
Transport Package
Carton
Specification
CE ISO
Trademark
Healicom
Origin
Jiangsu, China
Production Capacity
1000

Product Description

Ear lobe pulse oximeter for dog cat horse rabbit 
Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
Product Introduction:
WT60D Vet Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure SpO2 and pulse through animal's tongue or ear. It is applicable for use in family and pet hospital, etc.

Product Parameter:

Display mode

 color display

SpO2 measurement range

 0%~100 % (resolution: 1%)

Accuracy

 70%-100%: ± 2%

0%-69%: unspecified

PR measurement range

 30 bpm-250 bpm (resolulion: 1 bpm)

Accuracy

 ± 2 bpm or ±2%, whichever is greater.

Measurement performance in weak filling condition

 SP02 and pulse rate can be shown correct when pulse-filling ratio is 0.4%.

SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%, whichever is greater

Resistance to surrounding light

 The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

Power consumption

 <100 mA

Voltage

 DC 3.0 V

Power supply

 two AA batteries

Continuous working time

 44 hours in theory

Safety class

 Internally powered equipment, type BF applied part

 

Function
1.Small in volume, light in weight and convenient to carry.
2.Easy and simple to operate, low in power consumption.
3.With function menu.
4.Display of SpO2 value.
5.Display of PR value and bar graph.
6.Display of pulse waveform.
7.Adjustable screen brightness, PR sound indication.
8.Review function.
9.Clock function.
10.Audible prompt for over-limit and low battery.
11.Battery status indication.
12.Low battery indication.
13.Storage function for SpO2 and PR values, and data stored can be uploaded to PC.
14.Real-time data can be uploaded to PC.
15.External SpO2 probe can be connected.


Product details

Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit

Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit
Medical Veterinary Hospital Clinic Use Portable Handheld Vet Blood Oximeter Ear Lobe Pulse Oximeter for Dog Cat Horse Rabbit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now