Customization: | Available |
---|---|
Condition: | New |
Customized: | Non-Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Implement standard: 2010 guideline for CPR
Features:
1.The pupils are simulated on the LCD screen, which can simulate the narrowed, normal and dilated states of the pupils; the pupils are dilated in the rescue state, and the pupils are dilated and the light reflex will recover after the rescue is successful
2.The upper limb joints of the simulated human can move freely (pronation, supination, extension and retraction, flexion and extension, internal rotation, external rotation; wrist and elbow joints can flexion, extension, extension and retraction). patient moving
3.Equipment fault self-checking function: After starting up, the device automatically enters the self-checking program to check whether there is a fault in the device. If there is a fault, the user will be prompted to maintain it in time by voice
4.The button operation adopts fault-tolerant technology, and there is a voice prompt for wrong button operation, so as to avoid user's misoperation
5.Newly added detection of insufficient chest rebound rebound, and a voice prompt to the user
Simulated vital signs:
1) In the initial state: the carotid artery does not pulse, and the simulated pupils are dilated
2) During the compression process; the passive pulse of the human carotid artery is simulated, and the pulse frequency is consistent with the compression frequency
3) After the rescue is successful; the carotid artery beats spontaneously, the simulated pupils constrict, and the light reflex recovers
6.The standard airway can be opened, and the airway indicator light is on
7.Chest compression and artificial respiration can be performed in artificial hand position
Manual chest compressions:
1) The dynamic barcode indicator shows the compression depth: the correct compression depth (5-6cm area) is displayed by the green light of the barcode, the compression depth is not enough (less than 5cm) by the barcode yellow, and the compression depth is too deep (more than 6cm) by the dynamic movement of the barcode red light Feedback showing depth of CPR compressions
2) LCD counting and frequency display: record the specific reasons for pressing errors in detail (pressing too much, too little pressing, wrong pressing position, too fast, too slow, correct number of times, etc.)
3) Language prompts: Chinese voice prompts, detailing the specific reasons for pressing errors, so that trainers can correct them in time
8.During artificial mouth-to-mouth breathing (breathing):
1) The dynamic barcode indicator shows the tidal volume: the insufflated tidal volume is correct (500ml-600ml-1000ml) is displayed by the barcode green light, and the insufflated tidal volume is too small or too large respectively by the dynamic movement of the barcode yellow or barcode red indicator light Feedback Display Tidal Scale
2) LCD counting display: record the specific reasons for blowing errors in detail (according to excessive blowing volume, blowing into the stomach, too small blowing force, and correct number of blowing times)
3) Language prompts: Chinese voice prompts, detailing the specific reasons for pressing errors, so that trainers can correct them in time
9.Compression to artificial respiration ratio: 30:2 (single or double)
10.Operation cycle: effective 30 compressions and 2 artificial blows, 30:2 five cycles of CPR operation
11.Three modes of operation: available for CPR training, simulation assessment and actual combat assessment
1) Method 1: CPR training, compression and blowing can be performed
2) Method 2: Mode assessment, within the specified time, according to the 2015 International Cardiopulmonary Resuscitation Standard, the ratio of compression and insufflation is 30:2, complete 5 cycles of operation, statistical data and score, automatic scoring system
3) Method 3: actual combat assessment, within the set time frame, according to the 2015 international cardiopulmonary resuscitation standards, complete the pre-set assessment standards. The teacher can set the operating time range and the number of cycles by himself; statistical data printing results, automatic scoring system
CPR Display Features:
12.Electronic monitoring: Electronic monitoring of airway opening and compression parts, displaying correct and incorrect times of artificial respiration and external compression
13.Voice prompts: Chinese voice prompts throughout the training and assessment, the voice can be turned on and off, and the volume can be adjusted
Operation time, counted in seconds
Operating frequency: 100-120 times/minute or more
Examining the pupils: constricted and dilated vs.
Power supply status: 220V power supply is used, and the output power supply is 12V after being regulated by the stabilizer
Printer function:
Option to print operation process after completion of operation
There are two types of long and short printing, the short printing records the results of pressing and blowing during the entire operation process, and comprehensively judges and scores; the long printing covers the short printing to display the pressing and blowing waveforms
Standard set configuration:
An advanced cardiopulmonary resuscitation simulator
One advanced display controller
One luxury hand-pull and push-type human body hard plastic box
A resuscitative operation pad
Disposable disinfection mask (50 pieces/box) a box
One replaceable skin
Four interchangeable lung bags
Two rolls of thermal printing paper
instruction manual
Packing Specifications:
96*34*57CM G.W. 19KG
Standard components:
Full body manikin | 1PC |
Monitor | 1PC |
Portable plastic box | 1PC |
Temperature sensing printer | 1PC |
CPR operation pad | 1PC |
CPR face shield sheet (50pcs/box) | 50pcs/box |
Exchangeable lung bag | 5 PCS |
Exchangeable face skin | 1 PC |
Temperature sensing print paper | 2 roll |
Guide manual | 1 PC |