Surgical Equipment HA-15pro Trolley Anesthesia Machine
Application
Anesthesia systems are used in medical departments to perform general anesthesia on patients, perform controlled breathing or assisted breathing, and monitor and display the patient's ventilation HA-15Pro Anesthesia System parameters. Suitable for adults and children.
Performance characteristics
· Adopt electronic control and pneumatic control methods.
· Has a variety of alarm, prompt and protection functions.
· It has a power outage support function. When the mains power is cut off,it will automatically switch to the internal backup power supply.
· HA-15(A)Pro use 15-inch high-definition color LCD to display ventilation parameters, alarm information,wave forms and ring diagrams.
· Controlled by touch and button.
· Display background switching function (day/night.)
· Suitable for both adults and children.
· With capacity control, pressure limit and other working methods.
· Adopt temperature, flow and pressure compensation, Anesthetic evaporator with automatic altitude compensation function and zero-position self-locking.
· Built-in electronic flow meter.
· Linkage device to ensure that the O2 concentration is ≥25%.
· With O2 driving pressure insufficient alarm and N2O cut-off protection.
· Carbon dioxide monitoring module.
· Optional exhaust gas transmission and collection system.
· Optional anesthetic gas monitoring module.
TECHNICAL SPECIFICATION | |||||||||
Ventilation mode | Ventilator parameter range | ||||||||
IPPV, A/C (V-A/C, P-A/C), SIMV (V-SIMV, P-SIMV) , | Flowmeter | O2, N2O, AIR (0 ~ 10 L/min) | |||||||
PCV, PCV-PC, PCV-VG, PSV, MANUAL | Rapid oxygen supply | 25 L/min ~ 75 L/min | |||||||
Tidal volume(Vt) | 20 mL ~ 1500 mL | ||||||||
Alarm and protection | Adult: 300 mL ~ 1500 mL | ||||||||
Pressure limit | High (low) tidal volume alarm | Children: 20 mL ~ 300 mL | |||||||
Suffocation alarm | Alarm sound paused (mute) | I:E | 4:1 ~ 1:8 | ||||||
Hypoxia alarm | Airway high (low) pressure alarm | PEEP | OFF, 3 cmH2O ~ 30 cmH2O | ||||||
Absorber missed alarm | High (low) respiratory rate alarm | Pressure triggering sensitivity (PTr) | -20 cmH2O ~ -1 cmH2O | ||||||
Fan failure alarm | High (low) oxygen concentration alarm | Flow trigger sensitivity (FTr) | OFF, 0.5 L/min ~ 30 L/min | ||||||
Continuous pressure alarm | External power supply interruption alarm | Pressure control (PC) | 5 cmH2O ~ 70 cmH2O | ||||||
High (low) ventilation alarm | Maximum safety pressure ≤12.5 kPa | SIGH | OFF, 1/100 ~ 5/100 | ||||||
Internal backup power supply voltage undervoltage alarm | Suffocation time | OFF, 5 s ~ 60 s | |||||||
Ventilator outage (no tidal volume output) alarm | Respiratory rate | 1/min ~ 100/min SIMV: 1/min ~ 40/min | |||||||
The O2 and N2Oflow meters have linkage devices to ensure that the O2 | Adult: 4/min ~ 40/min | ||||||||
concentration is ≥25%. When O2is turned off, N2O is turned off | Children: 10/min ~ 100/min | ||||||||
automatically at the same time | Inspiratory time SIMV: 0.2 s ~ 10.0 s Adult: 0.3s ~ 10.0 s | ||||||||
Children: 0.2 s ~ 4.8 s | |||||||||
Working condition | Support pressure | 5cmH2O ~ 70cmH2O | |||||||
Supply voltage | 100-240 V~ | Rapid oxygen supply flow | 25L/min ~ 75L/min | ||||||
Power | frequency 50/60 Hz | Fresh gas outlet pressure | 30 kPa ~ 45 kPa | ||||||
Input power | 8A | ||||||||
Gas source | O2 , N2O, AIR (medical grade) | Oscillogram | |||||||
Air source pressure | 280 kPa ~ 600 kPa | P-T (pressure-time) | |||||||
Ambient temperature range | + 5 ºC ~ +40 ºC | F-T (flow-time) | |||||||
Relative humidity range | ≤ 80% | V-T (volume-time) | |||||||
Atmospheric pressure range | 860 hPa ~ 1060 hPa | ETCO2-T (ETCO2 -time) | |||||||
P-V loop (pressure-volume loop) | |||||||||
Monitoring parameter | P-F loop (pressure-flow loop) | ||||||||
Frequence(Freq) | 0 /min ~ 120 /min | F-V loop (flow-volume loop) | |||||||
Tidal volume (Vt) | 0 mL ~ 3000 mL | ||||||||
MV | 0 L/min ~ 100 L/min | Wooden case packing size | |||||||
Oxygen concentration | 15 Vol. % ~ 100 Vol.% | Wooden case packing size : L 925 * W 1060 * H 1620 mm | |||||||
G.W. : 125 KG |
1. What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.
2. Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper.
3. What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
4. What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge.
5. What is payment terms?
T/T, Credit Card, L/C, Western Union, PayPal, MoneyGram.