• Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor
  • Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor
  • Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor
  • Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor
  • Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor

Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor

Classification: Patient Monitor
Type: ECG
Certification: CE, ISO13485
Display Size: 12.1 Inch
Transport Package: Carton
Trademark: Healicom
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
HDAM-800
Origin
Jiangsu, China
Production Capacity
500 Piece/Month

Product Description

Product Description

HDAM-800 12.1 Medical Portable Multi-Parameter Patient Anesthesia Monitor Machine

Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor

The HDAM-800 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.

Features
Core
• Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products
• Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review

Body
12.1 inch high-brightness TFT LED
• Support display 9~13 waveforms
• Support 7 channel ECG waveform display simultaneously  
• Optional touch screen
• Optional HDMI output

Printer
• Built-in high-speed 50mm thermal printer (Brand: SEIKO, Japan)

Central System
• Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station. 
• Optional Support HL7 (Health Level Seven)

Alarm
• Three-level acousto-optic alarm 
• Sensor-off alarm 
• Paper out alarm 
• Support alarm review 
• Support alarm pause

Linux OS
• Support operation with mouse and computer keyboard (option) 
Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
Generate ID automatically when register a new patient
• Support medical history search by patient ID, name and mobile number 
• 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
Drug calculation and titration table 
• Support multi-language display 
• Support online software upgrading by net/USB


Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor
Technical Specifications
ECG
Lead mode 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
Protection Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
Gain 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto 
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
ECG signal range ±12 mV (Gain × 0.25)
Accuracy ±1bpm/ ±1%, whichever is greater
Resolution 1 bpm
Leakage Current < 10 μA
Baseline Recovery ≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
Bandwidth Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
Indication of Electrode Separation Every electrode (exclusive of RL)
Heart Rate
Measure range Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
Resolution 1 bpm
Accuracy ± 1% or ± 1bpm, whichever is greater
ST Measurement
Range -2.0 ~ +2.0 mV
Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
Other range unspecified
Resolution 0.01mV
Respiration
Method Impedance between RA-LL, RA-LA
Gain ×0.25, ×0.50, ×1, ×2, ×4
Respiration Rate 0bpm, 6 ~ 150 BrPM
Sweep speed 6.25 mm/s, 12.5 mm/s, 25mm/s
Resolution 1 BrPM
Accuracy ±2 bpm or ±2%, whichever is greater
Apnea Alarm 10 ~ 60 s
NIBP
Method Oscillometric
Measure mode Manual, Auto, STAT
Measure Interval in AUTO Mode 1~480 min
STAT mode cycle time Keep 5 minutes, at 5 seconds interval
Measure and Alarm Range Adult:          SYS:  30 ~ 270 mmHg
                    DIA:  10 ~ 220 mmHg     
                    MEAN:  20 ~ 235 mmHg 
Pediatric:     SYS:  40 ~ 235 mmHg
                    DIA:  10 ~ 220 mmHg     
                    MEAN:  20 ~ 225 mmHg
Neonate:      SYS:  30 ~ 135 mmHg
                     DIA:  10 ~ 110 mmHg     
                     MEAN:  20 ~ 125 mmHg
Static pressure accuracy ±3mmHg
Resolution 1mmHg
Accuracy Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
Over pressure Protection Dual protection via software & hardware 
Temperature
Technique Thermistor probe (2.25K)
Channel Dual-channel, provide T1; T2; ΔT
Measuring and Alarm Range 0.0 ºC~ 50 ºC (32ºF~ 122ºF) 
Unit Celsius (ºC), Fahrenheit ( ºF)
Resolution 0.1ºCor 1ºF
Accuracy ±0.1ºC(exclusive probe)
Pulse Rate
Measuring and Alarm Range 25~250bpm
Accuracy ±1% or ±1 bpm, whichever is greater
Resolution 1bpm

Company Profile

Operating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia MonitorOperating Room Cardiac Care Environments 6 Standard Parameters Anesthesia Monitor

FAQ

1.What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
 
2.What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. But if the machine is damaged due to rough handling during the transportation, we are free of any responsibility, but we will still provide help to the buyer issue claims against the shipping company or insurance company, thus all the spare parts or expenses should be borne by buyer.
 
3.What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.
 
4.Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper .
 
5.What is payment terms?
T/T in advance, L/C, Western Union, PayPal, MoneyGram.
 
6.Which shipping company usually using?
MAERSK-LINE, PIL, cosco, SAFMARINE, MARUBA, APL, CMA, CSAV, K-LINE, MSC, NYK, AND DHL, EMS, TNT, UPS FOR COURIER, buyer's option will be our priority, we will give suggestion according to the schedule and services.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now