Customization: | Available |
---|---|
Function: | Air Blender |
Theory: | Air Blender |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Function introduction:
The Air/Oxygen Blender is a precision proportioning device for mixing medical grade air and oxygen, which provides oxygen concentration and conveying gas flow controlled oxygen therapy for clinic. Besides as opened-end oxygen delivery, the Air/Oxygen Blender is supporting the use of infant incubator, infant radiant warmer, infant oxygen hood, oxygen therapy instrument, ventilator, CPAP, resuscitator and epidural instrument etc, especially suitable for neonatal intensive care unit and ward oxygen delivery. (Forbidden for the high blood oxygen disease).
Model & Specification |
KY-10A |
KY-10B |
KY-20A |
KY-20B |
KY-30A |
KY-30B |
|
Concentration valve |
Single |
Single |
Double |
||||
Flowmeter |
Single |
Double |
Double |
||||
Humidification bottle |
/ |
yes |
/ |
yes |
/ |
yes |
|
Gas bleed valve |
yes |
yes |
/ |
||||
Main part dimension |
123×63×71mm |
123×68×71mm |
123×68×71mm |
||||
Weight |
0.84kg |
0.84kg |
0.87kg |
||||
Single/double patient use |
Single patient use |
Single patient use |
Single/double patient use (adult) |
||||
Performance characteristics:
Oxygen concentration is 21%-100% continuous adjustable
Oxygen concentration and flow rate is adjustedseparately.
High precision regulating and continuous steady gas output
Pneumatic control without power supply
KY-30A and KY-30B is used for two patients simultaneously.
Specification:
1,Oxygen concentration adjusting range and accuracy
KY-10A and KY-10B:
Oxygen concentration adjusting range: 21%-100%.
Accuracy: ±3% O2(V/V).
KY-20A and KY-20B:
Oxygen concentration adjusting range: 21%-100%.
Accuracy: ±3% O2(V/V).
KY-30A and KY-30B:
Oxygen concentration adjusting range: 21%-100%.
Accuracy:
The accuracy of KY-30A and KY-30B blender is ±3% O2 (V/V)when use the single flow and the flow rate is more than 4L/min.
The accuracy of KY-30A and KY-30B blender is ±6% O2 (V/V)when use the doubleflow and both sides flow rate are more than 4L/min,
2,Flow rate adjusting range:
KY-10A, KY-10B, KY-30A and KY-30B:
Flow rate adjusting range: 0L/min -18L/min.
KY-20A and KY-20B:
Flow rate adjusting range: 0L/min -18L/min and 0L/min-3.5L/min.
Input gas source pressure: 207kPa-517kPa.
3,Alarm of gas source
Gas supply pressure difference>138kPa.
Interruption of gas supply.
Gas supply pressure >560kPa.
The Air/Oxygen Blender is built-in pneumatic sound alarm device with the whistle sound.
The alarm sound pressure level is>57dB(A).
The Reverse Gas Flow of zero (The reverse gas flow from either gas inlet to the other is zero).