Basic Info
  • Model NO.: HNT-2000
  • Certification: CE, FDA, ISO13485
  • Group: Infant
  • Medical Devices Reg./Record No.: Jyjxz20122260356
  • Temperature Control Range: 25°c~37°c
  • Radiant Box Horizon Angle Adjust Range: 0~±90° Step-Less
  • Mattress Tilt Adjust Range: 0~±10° Step-Less
  • RS-232 Connector: Yes
  • Packing Size: 110 ×90 ×110 Cm, 85 Kg
  • Transport Package: Wooden Case
  • Origin: China
  • Function: Infant Radiant Warmer
  • LCD Display: With LCD Display
  • Medical Device Regulatory Type: Type 2
  • Temperature Control Mode: Pre-Heat\Auto and Manual
  • Temperature Override Mode to: 38°c
  • Mattress Tray Size: 68cm×56cm
  • Mattress Tray Max. Load: 10 Kg
  • Mattress to Radiant Box: 81 Cm
  • Trademark: Healicom
  • Specification: ISO
  • HS Code: 90189090
Product Description
Standard composition
1. Temperature Control Mode: pre-heating control, servo control & manual control;
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Built-in APGAR Timer and >37°C preset function
4. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
5. Tilting Bed with Rotary Radiant Head;
6. X-ray Cassette Tray under infant bed, examination light of high illuminance;
7. Use anti-blast quartz infrared tube as radiant heating source.
 
Technical specification
PowerAC 110 / 220 V, 50Hz / 60Hz
Input Power≤1000VA
Temperature control range and relative specificationControl modePre-warm mode, manual mode, baby mode
Temperature control range25°C~37°C, for set temperature ≤37°C
37°C~38°C, for set temperature >37°C
Skin temperature sensor measure range20°C~42°C
Deviation between sensor measure temperature and control temperature≤0.5°C
Skin Sensor Precision≤0.3°C
Bed surface temperature Uniformity≤1°C
Temperature Rise Time≤45min
Bed tiltablecontinues adjustable in ±10°
AlarmSensor failure alarmAlarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarmAlarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power.
Deviation alarmAfter temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarmAlarm with audible and visual when power failure
APGAR timeAlarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes.
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.)Operate temperature range18°C~30°C
Store temperature range-20°C~+55°C
Environment HumidityOperate humidity range30%RH~75%RH
Store humidity range≤93%RH
Atmospheric pressureTransport and Store atmospheric pressure range500hPa~1060hPa
Operate atmospheric pressure range700hPa~1060hPa
Stream velocityAmbit environment stream velocity≤0.3m/s
 
 
SpecificationsHNT-1000HNT-2000HNT-2000B
Operational condition: 
Environment temperature+18°C~+30°C+18°C~+30°C+18°C~+30°C
Environment relative humidity30%~75%30%~75%30%~75%
Environment air velocity of flow<0.3m/s<0.3m/s<0.3m/s
Power requirement≤1000VA≤1000VA≤1000VA
Temperature control modeAutoPre-heat\auto and manualPre-heat\auto and manual
Temperature Control Range25°C~37°C25°C~37°C25°C~37°C
Temperature override mode to-----38°C38°C
Temperature sensor accuracy≤0.3°C≤0.3°C≤0.3°C
Mattress temperature uniformity≤2.0°C≤2.0°C≤2.0°C
Temperature rise time≤45 min≤45 min≤45 min
Heat output indicate0~100%0~100%0~100%
Radiant box horizon angle adjust range0~±90°step-less0~±90° step-less0~±90° step-less
Mattress Tray Size68cm×56cm68cm×56cm68cm×56cm
Mattress tilt adjust range0~±10° step-less0~±10° step-less0~±10° step-less
Mattress tray Max. load10 kg10 kg10 kg
Transfusion pole Max. load2 kg2 kg2 kg
Shelf Max. load2 kg2 kg2 kg
X-rayYesYesYes
RS-232 Connector----YesYes
Mattress to Radiant box81 cm81 cm81 cm
Heater infrared wavelength1~3 μm1~3 μm1~3 μm
APGAR Timer-----YesYes
Alarms 
Power failure alarmYesYesYes
Sensor failure alarmYesYesYes
Temperature deviation alarm±1.0°C±1.0°C±1.0°C
Over temperature alarm≤38.0°C≤38.0°C\≤39.0°C≤38.0°C\≤39.0°C
System failure alarm-----YesYes
Low-pressure suction-----------Yes
Pressure adjust range----------0~22Kp(0~165mmHg)
Operating noise----------≤55dB
White Phototherapy light------------1 set
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter)------------2 sets
Neonate resuscitation bag------------1 set
Packing size110×90×110 cm110  ×90 ×110 cm110 ×90 ×110 cm
Net weight85 kg85 kg95 kg
Gross Weight115 kg115 kg125 kg

 