Gold Member Since 2011
Audited Supplier
Healicom Medical Equipment Co., Limited

Infant Radiant Warmer, Infant Warmer, Radiant Warmer manufacturer / supplier in China, offering Hnt-2000b High-Quality Medical Infant Radiant Warmer, HL-05 Vertical Luminescence Shadowless Lamp, Hdc-99b-II Medical Gynecological Operation Table and so on.

(/ )

Supplier Homepage Product Infant Equipments Infant Radiant Warmer Hnt-2000b High-Quality Medical Infant Radiant Warmer

Hnt-2000b High-Quality Medical Infant Radiant Warmer

FOB Price: US $1,350 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1,350/ Piece
Get Latest Price
Production Capacity: 5000PCS/Year
Transport Package: Carton
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HNT-2000B
  • Function: Use for Babies
  • Certification: CE, ISO13485
  • Group: Children
  • Instant Parameter Display: Set Temp, Skin Temp, Heat Power Rate;
  • Input Power: ≤1000va
  • Trademark: Healicom
  • Origin: China
  • Type: Infant Radiant Warmer
  • Theory: Radial
  • LCD Display: Without LCD Display
  • Temperature Control Mode: Pre-Heating Control, Servo Control & Manual Contr
  • Power: AC 110 / 220 V, 50Hz / 60Hz
  • Keyword: Infant Radiant Warmer
  • Specification: CE, ISO
  • HS Code: 90189090
Product Description

Standard composition
Temperature Control Mode: pre-heating control, servo control & manual control;
Instant Parameter Display: set temp, skin temp, heat power rate;
Built-in APGAR Timer and >37°C preset function
Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
Tilting Bed with Rotary Radiant Head;
X-ray Cassette Tray under infant bed, examination light of high illuminance;
Use anti-blast quartz infrared tube as radiant heating source.

Technical specification

Power

AC 110 / 220 V, 50Hz / 60Hz

Input Power

≤1000VA

Temperature control range and relative specification

Control mode

Pre-warm mode, manual mode, baby mode

Temperature control range

25°C~37°C, for set temperature ≤37°C

37°C~38°C, for set temperature >37°C

Skin temperature sensor measure range

20°C~42°C

Deviation between sensor measure temperature and control temperature

≤0.5°C

Skin Sensor Precision

≤0.3°C

Bed surface temperature Uniformity

≤1°C

Temperature Rise Time

≤45min

Bed tiltable

continues adjustable in ±10°

Alarm

Sensor failure alarm

Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.

Over temperature alarm

Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C, cut off power.

Deviation alarm

After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.

Power failure alarm

Alarm with audible and visual when power failure

APGAR time

Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes.

Environment Temperature (It is a suggestion that please do not use outside of the allow environment.)

Operate temperature range

18°C~30°C

Store temperature range

-20°C~+55°C

Environment Humidity

Operate humidity range

30%RH~75%RH

Store humidity range

≤93%RH

Atmospheric pressure

Transport and Store atmospheric pressure range

500hPa~1060hPa

Operate atmospheric pressure range

700hPa~1060hPa

Stream velocity

Ambit environment stream velocity

≤0.3m/s

Add: Intra-low-pressure suction machine, white light photothreaphy unit, baby resuscitation bag, 7Loxygen cylinder*2, oxygen pressure meter and flow meter.
 
 

Specifications

HNT-1000

HNT-2000

HNT-2000B

Environment temperature

+18°C~+30°C

+18°C~+30°C

+18°C~+30°C

Environment relative humidity

30%~75%

30%~75%

30%~75%

Environment air velocity of flow

<0.3m/s

<0.3m/s

<0.3m/s

Power requirement

≤1000VA

≤1000VA

≤1000VA

Temperature control mode

Auto

Pre-heat,auto and manual

Pre-heat,auto and manual

Temperature Control Range

25°C~37°C

25°C~37°C

25°C~37°C

Temperature override mode to

-----

38°C

38°C

Temperature sensor accuracy

≤0.3°C

≤0.3°C

≤0.3°C

Mattress temperature uniformity

≤2.0°C

≤2.0°C

≤2.0°C

Temperature rise time

≤45 min

≤45 min

≤45 min

Heat output indicate

0~100%

0~100%

0~100%

Radiant box horizon angle adjust range

0~±90°step-less

0~±90° step-less

0~±90° step-less

Mattress Tray Size

68cm×56cm

68cm×56cm

68cm×56cm

Mattress tilt adjust range

0~±10° step-less

0~±10° step-less

0~±10° step-less

Mattress tray Max. load

10 kg

10 kg

10 kg

Transfusion pole Max. load

2 kg

2 kg

2 kg

Shelf Max. load

2 kg

2 kg

2 kg

X-ray

Yes

Yes

Yes

RS-232 Connector

----

Yes

Yes

Mattress to Radiant box

81 cm

81 cm

81 cm

Heater infrared wavelength

1~3 μm

1~3 μm

1~3 μm

APGAR Timer

-----

Yes

Yes

Power failure alarm

Yes

Yes

Yes

Sensor failure alarm

Yes

Yes

Yes

Temperature deviation alarm

±1.0°C

±1.0°C

±1.0°C

Over temperature alarm

≤38.0°C

≤38.0°C,≤39.0°C

≤38.0°C,≤39.0°C

System failure alarm

-----

Yes

Yes

Low-pressure suction

------

-----

Yes

Pressure adjust range

------

----

0~22Kp(0~165mmHg)

Operating noise

------

----

≤55dB

White Phototherapy light

------

------

1 set

7L Oxygen cylinder (with oxygen manometer & oxygen flow meter)

------

------

2 sets

Neonate resuscitation bag

------

------

1 set

Packing size

110×90×110 cm

110  ×90 ×110 cm

110 ×90 ×110 cm

Net weight

85 kg

85 kg

95 kg

Gross Weight

115 kg

115 kg

125 kg

Send your message to this supplier
Avatar
Miss Alice
Sales manager
*From:
To: Miss Alice
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category